How to get free Internet / FREE INTERNET on any SIM card everywhere you go 100% work - Duration: 12:13. Best text to speech software natural voices for tts. HDBD Hackers 1,343,882 views. Topcon lik 2015 full mega, topcon link 8.2 full mega, topcon link 8.2 gratis desde mega, descargar tocon link 8.2 full mega, descargar topcon link 8.2 gratis, programa para bajas datos de la estacion total topcon, programa para subir datos a la estacion total topcon, tranferir datos de la estacion total topcon, programa para convertir datos de. 7 COMMUNICATION MODES 7.2 Data File In When transferring data files from a PC to the GTS-820ASeries, the file received into the main directory. Data files CANNOT be received into a subdirectory. Data files CANNOT be transferred to the card memory. Files can only be transferred to the internal memory and then copied onto the card. Operating procedure Operation Display Make sure the instrument is ready and Communication F1 Protocol waiting for the data file before you command F2 Data file in the PC to send the file. F3 Data file out 1 Press [F2](Data file in) key. [F2] Data file in 2 Command the PC to send the file at this time. File name, amount of received data (Byte) / [TOPCON.DAT] Capacity of the file (Byte) and percentage of proceeding will be displayed. 0/ 8676 (0%) When the transfer is complete, the display will return to the main menu icons. 7.3 Data File Out Transferring a file from the GTS-820Ainternal memory or card memory to the PC is also possible. Operating procedure Operation Display Make sure the PC is ready and waiting before Communication the GTS-820sends the file. Spartiti per fisarmonica pdf to excel pdf. F1 Protocol F2 Data file in F3 Data file out 1 Press [F3](Data file out) key. [F3] Data file out F1 Internal memory F2 Card memory 2 Press [F1](Internal memory) or [F2](Card [F1] to[F2] JIS.DAT 1597 12-25 memory) key and press [ENT] key. [ENT] TOPCON.DAT 1089 10-05 Example: Internal memory FC7.TXT 2450 09-11 HILL.DAT 31777 08-19 Data file out ↑ ↓ 3 Select a file by pressing [F5](↑) or [F6](↓) key Select Data file out and press [ENT] key. A file File name, amount of sent data(Byte) / [ENT] [TOPCON.DAT] Capacity of the file (Byte) and percentage of proceeding will be displayed. 0/ 1089 (0%) When the transfer is complete, the display will returns to the file menu. 8 PARAMETERS SETTING MODE 8 PARAMETERS SETTING MODE 20:30:40 [Press [F6] key.] Prog Std Mem Comm Adj Para PARAMETERS SETTING MODE In this mode, setting of parameters regard with measuring, displaying and communications will be done. When a parameter is changed and set, the new value is stored into memory. Press [F6] key from the main menu icons, the following display will be shown. The parameter modes is classified in Measurement and Communication. Parameters F1 Measurement F2 Communication F3 Password 8.1 Parameter Setting Options 8.1.1 Parameters for Measurement and Display Menu Selecting Item Contents Ang. Unit deg / gon / mil Select degree(360°), gon(400G) or mil (6400M) for the measuring angle unit to be shown on the display. Select the minimum display angle reading ON or OFF. GTS-821A[ OFF:1' / ON:0.5' ] Min.Angle OFF / ON GTS-822A[ OFF:1' / ON:0.5' ] GTS-823A[ OFF:5' / ON:1' ] GTS-825A[ OFF:5' / ON:1' ] Tilt OFF / 1axis / 2axes Select the tilt sensor option for OFF, (1axis) vertical only or (2axes) vertical and horizontal. Select the error correction ON or OFF for collimation and error adjustment. OFF / ON Perform this item after complete section 9.4. ![]() For more information, refer to Section 9.4 “Adjustment of Compensation Systematic Error of Instrument” andSection 9.5 “Showing Constant List and Switch ON/OFF Compensation Systematic Error of Instrument”. V -0 Zenith / Level Select the vertical angle reading for Zenith 0 or Horizontal 0. It is able to retain presetting angle after turning power HAmem OFF / MEM. ON off.(MEMORY) Note: After changing this parameter, turn the power switch off once. Fine / Normal / Select the stopping accuracy of automatic rotation to required Turn angle. Coarse Fine:3' Normal:5' Coarse:10' Auto.Aim Fine / Normal / Select the accuracy of automatic collimation. 8 PARAMETERS SETTING MODE Dist. Unit METER /FEET Select the distance measuring unit Meter or Feet shown on the display. Select the meter / feet conversion factor. US SURVEY feet C.F.
0 Comments
Leave a Reply. |